SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

LAR1:gu
 

Search: LAR1:gu > (2010) > Journal article > Båth Magnus 1974 > Eriksson Ida > Determination of th...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Determination of the detective quantum efficiency of gamma camera systems: a Monte Carlo study

Eriksson, Ida (author)
Department of Medical Physics, Karlstad Hospital, Karlstad, Sweden
Starck, Sven-Åke (author)
Jönköping University,HHJ, Avdelningen för naturvetenskap och biomedicin
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
 (creator_code:org_t)
2010-02-19
2010
English.
In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 219-227
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The purpose of the present work was to investigate the validity of using the Monte Carlo technique for determining the detective quantum efficiency (DQE) of a gamma camera system and to use this technique in investigating the DQE behaviour of a gamma camera system and its dependency on a number of relevant parameters. The Monte Carlo-based software SIMIND, simulating a complete gamma camera system, was used in the present study. The modulation transfer function (MTF) of the system was determined from simulated images of a point source of (99m)Tc, positioned at different depths in a water phantom. Simulations were performed using different collimators and energy windows. The MTF of the system was combined with the photon yield and the sensitivity, obtained from the simulations, to form the frequency-dependent DQE of the system. As figure-of-merit (FOM), the integral of the 2D DQE was used. The simulated DQE curves agreed well with published data. As expected, there was a strong dependency of the shape and magnitude of the DQE curve on the collimator, energy window and imaging position. The highest FOM was obtained for a lower energy threshold of 127 keV for objects close to the detector and 131 keV for objects deeper in the phantom, supporting an asymmetric window setting to reduce scatter. The Monte Carlo software SIMIND can be used to determine the DQE of a gamma camera system from a simulated point source alone. The optimal DQE results in the present study were obtained for parameter settings close to the clinically used settings.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Eriksson, Ida
Starck, Sven-Åke
Båth, Magnus, 19 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Radiation protec ...
By the university
University of Gothenburg
Jönköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view